GPC/SEC & Molecular Weight Analysis

Core expertise

GPC/SEC & Polymer Molecular Weight Analysis

Multi-detector size exclusion chromatography for molecular weight, distribution, branching and solution behaviour — with scientific interpretation of what the data means for your material.

Scope

What this service can answer

Molecular weight governs mechanical performance, processability, degradation behaviour and regulatory comparability. We select the column set, solvent system and detector configuration appropriate to your polymer, then interpret the distribution in the context of your product.

Has the molecular weight changed?

Compare processed, sterilized, aged or field-returned material against a control or reference lot.

Is my material branched?

Conformation plots from light scattering and viscometry indicate long-chain branching and structural differences.

Is this lot equivalent?

Distribution overlays and dispersity comparisons support lot-to-lot and supplier-to-supplier assessment.

What is the absolute molecular weight?

Light scattering provides molecular weight independent of column calibration standards.

Measurements

Parameters available

Mn

Number-average molecular weight

Sensitive to low molecular weight fractions and oligomers.

Mw

Weight-average molecular weight

Correlates with melt behaviour and mechanical performance.

Mz

z-average molecular weight

Emphasizes the high molecular weight tail.

Đ

Dispersity (Mw/Mn)

Breadth of the molecular weight distribution.

MWD

Molecular weight distribution

Full distribution curve, including shoulders and tails.

[η]

Intrinsic viscosity

Solution behaviour and hydrodynamic volume via viscometry.

Rg

Radius of gyration

Molecular size in solution from light scattering.

g'

Branching index

Contraction factor indicating long-chain branching.

Configurations

Detector configurations

Configuration

Detectors

Best used for

Key outputs

Conventional GPC/SEC

RI (± UV)

Routine comparison against calibration standards

Relative Mn, Mw, Mz, Đ, MWD

Light scattering (MALS)

RI + MALS

Absolute molecular weight without column calibration

Absolute Mw, Rg, aggregation

Viscometry

RI + viscometer

Solution behaviour and universal calibration

[η], Mark–Houwink parameters

Triple detection

RI + MALS + viscometer

Complex, branched or novel polymers

Absolute M, Rg, [η], branching (g, g′)

UV-selective

RI + UV/PDA

Copolymers and chromophore-containing species

Composition trends across the distribution

Column set, solvent, temperature and detector combination are selected per material. High-temperature and aqueous configurations are assessed case by case.

Scroll horizontally to view the full table.

Approach

How the work is designed

Method selection

Solvent, column chemistry, temperature and calibration approach chosen for the polymer and the question.

Method development

Where no suitable method exists, we develop and document one, including solubility and recovery assessment.

Comparative studies

Structured control-versus-test designs for processing, sterilization, ageing and supplier changes.

Interpretation

Reporting that states what the distribution indicates about the material, not only the numbers.

Examples

Example project scenarios

Sterilization effect on a resorbable device polymer

GPC/SEC before and after irradiation to quantify chain scission, supported by DSC for thermal change.

Incoming resin qualification

Distribution overlays across supplier lots to define an acceptable molecular weight window.

Novel branched polymer characterization

Triple detection with conformation plots to describe branching relative to a linear reference.

Samples

Sample requirements

Typically 20–100 mg of solid polymer, or 5–10 mL of solution, per analysis.

Provide known solvents, solubility observations and any additives or fillers present.

Include a control or reference lot wherever a comparison is the objective.

Safety data sheets are required before shipment. Specific requirements are confirmed during project scoping.

Quality

Quality and accreditation context

Accreditation applies to specific methods within a defined scope rather than to all work performed. [Verified accreditation details] — applicable accredited methods are confirmed during project scoping.